Deutsch, Heliomolar, Flow – Ivoclar Vivadent Heliomolar Flow User Manual

Page 3

Advertising
background image

Additional notes
Heliomolar Flow may also be applied on polymerized
material. In order to attain appropriate adhesion between
the interfaces, the polymerized material should be
roughened and cleaned prior to the application of fresh
Heliomolar Flow.

Warning
– Avoid contact of Heliomolar Flow with skin/mucous

membrane and eyes. Uncured Heliomolar Flow may cause
slight irritation and may result in sensitization against
methacrylates.

– Commercial medical gloves do not provide protection

against the sensitizing effect of methacrylates.

Storage
– Close syringes immediately after use. Exposure to light

causes premature polymerization.

– Do not use Heliomolar Flow after the indicated date of

expiration.

– Storage temperature: 2–28 °C / 36–82 °F.
– Shelf life: see date of expiration on label/package.

Keep out of the reach of children.
For use in dentistry only.

Date information prepared
12/2009, Rev. 1

Manufacturer
Ivoclar Vivadent AG
FL-9494 Schaan / Liechtenstein

This material has been developed solely for use in dentistry. Processing should be
carried out strictly according to the Instructions for Use. Liability cannot be accep-
ted for damages resulting from failure to observe the Instructions or the stipulated
area of application. The user is responsible for testing the material for its suitability
and use for any purpose not explicitly stated in the Instructions. Descriptions and
data constitute no warranty of attributes and are not binding.

Heliomolar

®

Flow

Gebrauchsinformation

Beschreibung
Heliomolar Flow ist ein mikrogefülltes, röntgenopakes
Composite und härtet mit Licht der Wellenlänge im Bereich
von 400–500 nm (Blaulicht) aus.

Farben
Heliomolar Flow ist in folgenden 7 Farben lieferbar:
Chromascop

A–D Farben

105

110

A1

140

A2

210

A3

410

D3

110T

A1T

420T

Zusammensetzung
Die Monomermatrix besteht aus Bis-GMA,
Urethandimethacrylat und Triethylenglycolmethacrylat
(40.5 Gew.%). Die Füllstoffe bestehen aus hochdispersem
Siliziumdioxid, Ytterbiumtrifluorid und Copolymer
(59 Gew.%). Zusätzlich enthalten sind Katalysatoren,
Stabilisatoren und Pigmente (0.5 Gew.%).
Der Gesamtgehalt an anorganischem Füller beträgt
30 Vol.% resp. 51 Gew.%, die Partikelgrösse liegt
zwischen 0.04 und 0.2 µm.

Indikation
– Füllungen der Klasse V (Zahnhalskaries, Wurzelerosionen,

keilförmige Defekte)

Deutsch

HeliomorFlow-GI-WE3_Rev1.qxd:HeliomorFlow-Gi-WE3-NEU.qxd 15.12.2009 17:41 Uhr Seite 3

Advertising