Power supply, 1 power supply – Datalogic Scanning DS4600A User Manual

Page 20

Advertising
background image

DS4600A

2

2.3.1 Power

Supply


Power can be supplied to the scanner through the pins provided on the 25-pin
connector used for communication with the host (Figure 6):

DS4600A

13

25

VS

GND

1

CHASSIS

Earth Ground

USER INTERFACE

CHASSIS

GND

V+ (10 - 30 Vdc)

Figure 6 - Power Supply Connections


or through the jack connector on the side of the 25-pin connector for connections to a
UL Listed Direct Plug-in Power Unit (Figure 7). If the jack input is used to supply
power to the DS4600A, pin 13 is automatically disconnected; the supply voltage for
the external trigger remains on pin 9. The plug connector is not supplied with the
DS4600A.

V+ (10 - 30 Vdc)

Jack

Plug

GND

Figure 7 - Power Supplied Using the Jack Connector


For Standard models, the power must be between 10 and 30 Vdc only. There is a
current peak of about 1A at 10 V during power on caused by the motor starting.

For Integrated Heater models, the power must be 24Vdc only.

It is recommended to connect pin 1 (CHASSIS) to a common earth ground.