Technical features, 6 technical features – Datalogic Scanning DS4600A User Manual

Page 56

Advertising
background image

DS4600A

6

6 TECHNICAL

FEATURES


ELECTRICAL FEATURES

DS4600A-XXX0 DS4600A0-2XX5

Power

Supply Voltage

10 to 30 Vdc

24 Vdc

Power Consumption max.

6 W

12W

Serial Interfaces

Main

RS232, RS485 full-duplex, RS485 half-duplex

(20 mA C.L. only with C-Box 100 and INT-30 accessory )

Auxiliary RS232

Baudrates

1200 to 115200

Inputs

External Trigger, IN1, IN2

(optocoupled NPN or PNP)

Voltage max.

30 Vdc

Input Current max.

25 mA

Outputs

User-defined OUT1 and OUT2

(optocoupled open emitter, open collector)

VCE max. 40

Vdc

Collector Current max.

40 mA continuous; 130 mA pulsed

VCE saturation

1V at 10 mA max.

Power Dissipation max.

90 mW at 40

°C (Ambient temp.)

OPTICAL FEATURES

Light Source

Semiconductor laser diode

Wavelength (Note 1)

630 ~ 680 nm

Safety Class

Class 2 – EN60825-1; CDRH

READING FEATURES

(Note 2)

200X / 300X

210X / 310X

220X / 320X

Aperture Angle

66°

70°

60°

Maximum Resolution

0.25 mm

(10 mils)

0.50 mm
(20 mils)

0.20 mm

(8 mils)

Max. Reading Distance

See reading diagrams

Scan Rate

800 scans/sec

USER INTERFACE

LED Indicators

Ready, Good Read,

External Trigger , Data Transmission

44

Advertising