INSTALLATION

2

2.3.2

Main Serial Interface


The signals relative to the following serial interface types are available on the
input/output connector of the DS4600A.

The main serial interface type and its relative parameters (baud rate, data bits,
etc.) are selected via software either using the WinHost utility program or Host
Mode programming. For more details refer to the section "Main Interface Menu"
in the WinHost Help On Line.

Details regarding the connections and use of the main interface selection are given in
the next paragraphs.

RS232 Interface


The serial interface is used in this case for point-to-point connections; it handles
communication with the host computer and allows both transmission of code data
and the configuration of the scanner. This is the default interface.

The following pins of the 25-pin connector are used for RS232 interface connection:

Pin Name

Function

2 TX232

transmitted

data

3 RX232

received

data

4

RTS232

request to send

5

CTS232

clear to send

7

SGND Main

signal ground main interface

It is always advisable to use shielded cables. The overall maximum cable length
must be less than 15 m (49.2 ft).

RTS/CTS HARDWARE HANDSHAKING ENABLED

DS4600A

USER INTERFACE

7

SGND Main

SGND

RTS232

4

DCD

CTS232

5

DTR

RX232

3

TXD

TX232

2

RXD

Earth

Ground

Figure 8 - RS232 Main Interface Connections