Rs485 full-duplex interface – Datalogic Scanning DS4600A User Manual

Page 22

Advertising
background image

DS4600A

2

The RTS232 and CTS232 signals control data transmission and synchronize the
connected devices.


Figure 9 - RS232 Control Signals


If the RTS/CTS handshaking protocol is enabled, the DS4600A activates the RTS232
output to indicate a message is to be transmitted. The receiving unit activates the
CTS232 input to enable the transmission.

RS485 Full-Duplex Interface


The RS485 full-duplex (5 wires + shield) interface is used for non-polled
communication protocols in point-to-point connections over longer distances (max
1200 m / 3940 ft) than those acceptable for RS232 communications or in electrically
noisy environments.

The following pins of the 25-pin connector are used for RS485 full-duplex
communications:

Pin Name

Function

2

TX485+

RS485 transmitted data +

4

TX485-

RS485 transmitted data -

3

RX485+

RS485 received data +

5

RX485-

RS485 received data -

7

SGND Main

signal ground main interface


10