Installation – Desa CCL3018PTA User Manual

Page 12

Advertising
background image

www.desatech.com

113097-01C

12

See chart below for minimum permanent flue

opening you must provide. Attach damper clamp

so the minimum permanent flue opening will be

maintained at all times.

INSTALLATION

Continued

INSTALLING HEATER BASE
ASSEMBLY

CAUTION: Do not remove the

data plates attached to the heater

base assembly. The data plates

contain important warranty and

safety information.

WARNING: You must secure

this heater to fireplace floor. If

not, heater will move when you

adjust controls. Moving heater

may cause a gas leak.

WARNING: If installing in a

sunken fireplace, special care

is needed. You must raise the

fireplace floor to allow access

to heater control panel. This

will insure adequate air flow

and guard against sooting and

controls being damaged. Raise

fireplace floor with noncombus-

tible material. Make sure material

is secure.

CAUTION: Do not pick up

heater base assembly by the

burner. This could damage

heater. Only handle base as-

sembly by grates.

IMPORTANT:

Make sure the heater burners are

level. If heater is not level, heater will not work

properly. For thermostat models, avoid damage

to thermostat bulb. Avoid nicks or sharp bends

in thermostat bulb wire. Keep thermostat bulb

in mounting bracket until ready to mount base

to floor. See Optional Positioning Of Thermostat

Sensing Bulb, page 28.
Installation Items Needed
• hardware package (provided with heater)

• approved flexible gas hose (not provided) (if

allowed by local codes)

• sealant resistant to propane (propane/LP) gas,

not provided

• electric drill with 3/16" drill bit

• flathead screwdriver
1. Apply pipe joint sealant lightly to male threads

of the fitting to be threaded into gas regulator.

Connect approved flexible gas hose to gas

regulator of heater (see Figure 11).

IMPORTANT:

Hold gas regulator with

wrench when connecting flexible gas hose.

2. Locate masonry screws in hardware package.
3. Position heater base assembly in fireplace.
4. Place logs in their proper position on heater base,

see Installing Logs on page 16.

5. Center heater base and logs front-to-back and

side-to-side in fireplace.

6. Carefully remove logs without moving heater

base.

Area of Various Standard

Round Flues

Diameter (in.)

Area (sq. in.)

5"

20 sq. inches

6"

29 sq. inches

7"

39 sq. inches

8"

51 sq. inches

Chimney

Minimum Permanent

Height (ft.)

Flue Opening (sq. in.)

6' to 15'

39 sq. inches

15' to 30'

29 sq. inches

Figure 11 - Attaching Flexible Gas Hose

to Heater Gas Regulator

Heater Gas
Regulator

Flexible Gas Hose
(if allowed by local codes)

Fitting

Advertising