INSTALLATION AND CLEARANCES
(Vent-Free Operation Only)

WARNING: Maintain the

minimum clearances. If you

can, provide greater clearances

from floor, ceiling and adjoining

wall.

MINIMUM FIREPLACE CLEARANCE

TO COMBUSTIBLE MATERIALS

Log Size

Side Wall

Ceiling

18", 24", 30"

16"

42"

LOG SIZING REQUIREMENTS

Minimum Firebox

Log

Front

Rear *

Size Height Depth

Width

Width

18"

17"

14"

24"

20"

24"

17"

14"

28"

21"

30"

17"

14"

34"

24"

* Measured at 14" depth.
Carefully follow the instructions below. This will

ensure safe installation into a masonry, UL127-

listed manufactured fireplace or certified vent-free

firebox.
Minimum Clearances For Side
Combustible Material, Side Wall and
Ceiling
A. Clearances from the side of the fireplace

cabinet to any combustible material and wall

should follow diagram in Figure 4.

Example:

The face of a mantel, bookshelf,

etc. is made of combustible material and

protrudes 3

1

/

2

" from the wall. This combus-

tible material must be 4" from the side of the

fireplace opening (see Figure 4).

Note:

When installing your gas logs into

a manufactured firebox, follow firebox

manufacturerʼs instructions for minimum

clearances to combustible materials.

B. Clearances from the top of the fireplace opening

to the ceiling should not be less than 42 inches.

INSTALLATION

Continued

Figure 4 - Minimum Clearance for

Combustible to Wall

*Minimum 16 inches from Side Wall

Example

*

NOTICE: Manual control heaters

may be used as a vented product.

If so, you must always run heater

with chimney flue damper open.

If running heater with damper

open, noncombustible material

above fireplace opening is not

needed. Go to

Installing Damper

Clamp Accessory for Vented

Operation, page 11.

Minimum Noncombustible Material
Clearances

If Not Using Mantel

Note:

If using a mantel, proceed to If Using

Mantel, page 10. If not using a mantel, follow the

information below.
You must have noncombustible material(s) above

the fireplace opening. Noncombustible materials

(such as slate, marble, tile, etc.) must be at least

1/2 inch thick. With sheet metal, you must have

noncombustible material behind it. Noncombus-

tible material must extend at least 8" up (for all

models). If noncombustible material is less than

12", you must install the fireplace hood accessory

(24" and 30" models only). See Figure 5, page 10

for minimum clearances.
IMPORTANT:

If you cannot meet these minimum

clearances, you must operate heater with chimney

flue damper open. Go to Installing Damper Clamp

Accessory for Vented Operation, page 11.