U

2

=20V+0,04xI

2

U

2

U

U

2

I

2

I

2

Point to point welding

Point to point welding is necessary then when the seam to be welded does not withstand heat of

continuous arc and welding has to be carried out by interrupting arc. The reason is usually thin

materials or variable fittings.
The machine has characteristic curve which makes interrupting of arc easier when electrode is

drawn further from seam.

6. maIntenance

The amount of use and the working environment shoud be taken into consideration when

planning the frequency of maintenance of the machine. Careful use and preventive maintenance

will help to ensure trouble-free operation.

6.1. cables

Check the condition of welding and connection cables daily. Do not use damaged cables.
Make sure that the mains cables in use are safe and according to laid down regulations.
The repair and mounting of a mains connection cables should be carried out only by an

authorized electrician.

Carbon arc gouging

In carbon arc gouging there are dynamic constant voltage curves. If the tip gouging carbon

makes a short circuit, the power source will make an strong increase to the current, the short

circuit ends rapidly and the arc will remain or reignite easier.

5. coolIng unIt supply

1~230 v / 250 va

Kemppi Pro Evolution 4200 and 5200 power sources have as stardard a by productive earthed

outlet X16 isolated safety transformer. Procool cooling unit is connected to this outlet.

U is limited below max. voltage

of machine

statically constant current

dynamically constant voltage