If changing the mains cable take into consideration the following:

The cable is entered into the machine through the inlet ring on the rear panel of the machine and

fastened with a cable clamp (05). The phase conductors of the cable are coupled to connectors

L1, L2 and L3. The earth protection coloured green-yellow is coupled to connector

If you are using 5-lead cable, you must connect neutral conductor with

terminal N.

*) In cables of S type there is a protective grounding conductor coloured green-yellow.

2.2.2. Welding and earth cables

Recommended copper cables with cross-sectional area are as follows:
Kemppi Pro Evolution 3200

50 ... 70 mm

2

Kemppi Pro Evolution 4200

70 ... 90 mm

2

Kemppi Pro Evolution 5200

70 ... 90 mm

2

In enclosed table are shown typical load capacities of rubber insulated copper cables, when

ambient temperature is 25 ºC and lead temperature is 85 ºC.

CABLE DUTY CYCLE ED

VOLTAGE LOSS / 10m

...........................100% .........60% ........... 30%
50 mm

2

..............285 A .........370 A ......... 520 A ...........0,35 V / 100 A

70 mm

2

..............355 A .........460 A ......... 650 A ...........0,25 V / 100 A

95 mm

2

..............430 A .........560 A ......... 790 A ...........0,18 V / 100 A

Do not overload welding cables due to voltage losses and heating.
Fasten the earth clamp of the return current cable carefully, preferably direct onto the piece to be

welded. The contact surface of the earth clamp should always be as large as possible.
Clean the fastening surface from paint and rust.

3. operatIon control swItches and

potentIometers and theIr use

3.1. maIn swItch I/o

When you turn the switch into I-position, pilot lamp H11 on the front face is illuminated and the

machine is ready for use.

Always turn the machine on and off with the mains switch, never use the

mains plugs as a switch.

Sizes of the mains cables and fuse ratings for the machine at 100% duty cycle are specified in

the table below:

Rated voltage

Mains voltage range

Fuses,
slow-blow

Connection
cable *) mm

2

Pro Evolution 3200

400 V 3~

360 V… 440 V

25 A

4 x 6.0 S

Pro Evolution 4200

400 V 3~

360 V… 440 V

35 A

4 x 6.0 S

Pro Evolution 5200

400 V 3~

360 V… 440 V

35 A

4 x 6.0 S

Pro Evolution 3200 MVU 400 V 3~ 230 V 3~

360 V… 440 V 200 V… 260 V 35 A

4 x 6.0 S

Pro Evolution 4200 MVU 400 V 3~ 230 V 3~

360 V… 440 V 200 V… 260 V 50 A

4 x10 S

Pro Evolution 5200 MVU 400 V 3~ 230 V 3~

360 V… 440 V 200 V… 260 V 60 A

4 x 16 S