6.2. power source

Note! Disconnect the plug of the machine from the mains socket and wait

approx. 2 minutes (capacitor charge) before removing the cover plate.

Check at least every half year:
- Electric connectors of the machine - clean the oxidized parts and tighten the loosened ones.
- Note! You must know correction tension torques before starting the reparation of the joints.
- Clean the inner parts of the machine from dust and dirt e.g. with a soft brush and vacuum

cleaner. Also clean the ventilation net behind the front grate.
- Do not use compressed air, there is a risk that dirt is packed even more tightly into gaps

of cooling profiles.
- Do not use pressure washing device.
- Only authorized electrician shall carry out repairs to the machines.

6.3. regular maIntenance

Kemppi Service Workshops make regular maintenance according to agreement.
The major points in the maintenace procedure are listed as follows:
- Cleaning of the machine
- Checking and maintenance of the welding tools
- Checking of connectors, switches and potentiometers
- Checking of electric connections
- Meter checking
- Checking of mains cable and plug
- Damaged parts or parts in bad connection are replaced by new ones
- Maintenace testing. Operation and performance values of the machine are checked, and

adjusted when necessary by means of test equipment.

7. operatIon dIsturbances

In case of problems contact the Kemppi works in Lahti, Finland, or your local Kemppi dealer.
Check the maintenace objects before the machine is sent to the Service Workshop.

7.1. operatIon of the overload protectIon

Yellow pilot lamp H12 of thermal protection is lit when thermostat has operated due to

overheating of machine.

7.2. control fuses

Fuse F11, 6,3 A delayed, on the rear wall of machine is as protection for connection of auxiliary

devices X14-15.

Voltage unit for auxiliary devices (1~230 V/240 VA) has a fuse of its own F12 1,0 A delayed.

Use same type and rating of fuse which is marked beside the fuse adapter.

Damage caused by a wrong type fuse is not covered by the guarantee.

The thermostat of machine will operate, if machine is continuously loaded over rated values or

cooing air circulation is blocked.
Cooling fan cools down the machine and when the pilot lamp is not lit the machine is automati-

cally ready for welding.