Other user functions, Jumpers – Kemppi Promig 540R User Manual

Page 15

Advertising
background image

14 – Promig 540R, Promig 120R/0425

©

KEMPPI

OY

Promig 540R, Promig 120R/0423 – 15

©

KEMPPI

OY

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

5. OTHER USER FUNCTIONS

Selection between gas-cooled and water-cooled gun is made using the switch inside the control

unit.
Wire inch switch function is in the front of control unit and feeder unit.
– displays main motor current on welding current window and gun motor current on voltage

display window

– inch speed is set by local control setting (panel)
Gas purge switch is in the front of control unit and feeder unit.
– gas purge when pressed
Gas valve is mounted inside the feeder unit but it can also be moved into the control unit where

there is a place for it.
A gas pressure switch can be mounted inside the control unit.
Inside the control unit there is a 20 kg MIG wire spool system.

6. JUMPERS

1. Selection of wire feeder address

102, set 1

105, set 2

2. Robot control input voltage range for analog channels:

0-10 V

0-5 V

3. Selection of max. wire feed speed for feed unit 1

0-18 m, delivery setting

0-25 m

4. Selection of max. wire feed speed for feed unit 2

0-18 m / min

0-25 m / min

Advertising