2.4. ASSEMBLY OF MIG SYSTEM

Assemble the units according to the mounting instructions delivered with the unit.

1. Installation of power source

Read paragraph “INSTALLATION” in operation instructions for PRO power sources and

install accordingly.

2. Mounting of PRO power source to transport wagon

P 20

see air-cooled MIG system

P 30W

see liquid-cooled MIG system

P 40

see air-cooled MIG system

3. Put PROMIG onto the power source and lock it with bolts to handles of powersource.
4. Installation of the fieldbus card

MXE 6263504, installation instruction 4279220
Open side plate and install fieldbus card by mounting above the interface card with two M3 nut.
See mounting instructions.

5. Connecting cables

Connect cables according to paragraph ”UNITS, ACCESSORIES, CABLES”.

6. Max. wire feed speed

By delivery, the max. wire feed speed is 18 m/min, which is enough for most welding

applications. If you need a higher speed, you can increase the wire feed speed to 25 m/min

by replacing the gear wheel on motor shaft. The high ratio wheel (*D40*) is delivered with

the feed unit.

Changing the maximum wire feed speed:

– Open side plate and remove JUMPER 3 on control card A001. This alters the tacho

feedback ratio to 0 - 25 m/min

Fieldbus card