Minutes per db help screen, Leap years, Daylight savings occurrences – Lencore Spectra Classic: LP-2 User Manual

Page 10: Reset button

Advertising
background image


-10-

every 3 days, and will last for 18 days (6 x 3 = 18), not counting Saturday and Sunday.

Minutes per dB help screen

Press 0 (for the menu screen)
Press 3
Press 1 or 2
Press 1, 2, 3, 4, 5, 6 or 7
Press 1 or 2

Press 3
Press # to see next three lines, or * to exit

Press 0
Press 0
Press 0

Press 0

Help screen text: (reads)

Minutes per dB specifies the number of minutes it will take to change attenuation by 1 dB.

Example: Assume the following.
Attenuation setting for 5 PM to 8 AM is -6 dB. Attenuation setting for 8 AM to 5 PM is 0 dB.
The Min / dB setting for the same time period is 5 minutes. Also assume that the time
of day is 8:00 AM. This means that at 8:05 AM, attenuation will change to -5 dB. 8:10 AM,
attenuation will change to -4 dB. 8:15 AM, attenuation will change to -3 dB. 8:20 AM, atten-
uation will change to -2 dB. 8:25 AM, attenuation will change to -1 dB. And finally at 8:30
AM, attenuation will change to 0 dB. Attenuation will remain at 0 dB level until 5:00 PM. 5:05
PM, attenuation will change to -1 dB. 5:10 PM, attenuation will change to -2 dB. 5:15 PM,
attenuation will change to -3 dB. 5:20 PM, attenuation will change to -4 dB. 5:25 PM,
attenuation will change to -5 dB. And finally at 5:30 PM, attenuation will change to -6 dB.
Attenuation will remain at -6 dB level until a difference in dB level setting is encountered
the following day.

Leap years


Leap years are preprogrammed and automatically account for February 29 when
appropriate.

Daylight savings occurrences


The first Sunday in April at 2:00 A.M., the hour will be advanced to 3:00 A.M. On the
last Sunday in October at 2:00 A.M., the hour will be set back to 1:00 A.M.

Reset button


When the reset button is pressed or power is first applied to the timer, all user

programming will be lost. The date and time will also be incorrect. You must first re-
enter the correct date and time. Attenuation values, minutes per dB values and

Advertising