Specifications, Power requirements power consumption, Zones – Lencore Spectra Classic: LP-2 User Manual

Page 13: Programming, Clock accuracy, Battery

Advertising
background image


-13-

used by default.

Acclimate dB's = -6

Days per dB = 3

The date and time will need to be reentered after a reset.

SPECIFICATIONS

Power requirements

Power consumption

24 VAC

RMS

, 60 Hz

26-Watts maximum

Zones

2 independent zones except for acclimate dB's
500 LM-6 Master units per zone

Programming

Programmed attenuation range: 0 to -9 dB
Slide control adjustment range: +5 to -5 dB
Minutes per dB range: 1 to 6 minutes
Acclimate attenuation range: -1 to -9 dB, 0 dB when off
Acclimate days per dB range: 1 to 6 days
Acclimate length: 1 to 54 days not counting Sat. & Sun.
Maximum overall attenuation range: +5 to -18 dB
Programmed events: 24 events per day for each zone

Clock accuracy

±2 seconds per day

Battery

Rechargeable sealed lead-acid, 12 Volt, 2.2 Ah, provides approximately 24
hours backup power

TIMER RECORD SHEET

ZONE 1

Attenuation/Minutes per dB

HOUR Mon Tue Wed Thu Fri

Sat Sun

12:00 AM

1:00 AM

2:00 AM

3:00 AM

4:00 AM

5:00 AM

6:00 AM

Advertising