7.1.1

SS7_BOARD – Configure Dialogic

®

DSI SS7MD Network Interface Board

Synopsis

Command to configure a DSI SS7MD Board in the system.

Syntax

SS7_BOARD <board_id> <board_type> <flags> <code_file> <run_mode>

Example

SS7_BOARD 0 SS7MD 0x0000 ss7.dc6 LSL

Parameters

The SS7_BOARD command includes the following parameters:

<board_id>
The logical identity of the board in the range from 0 to one less than the number of boards supported
(typically, 0 to 3).

<board_type>
The board type within the system. Possible values are:

— SS7MD – for DSI SS7MD Boards

<flags>
A 16-bit value that provides additional level 1 configuration for the board. The meaning of each bit may
vary with different board types. The bits have the following significance:

— Bit 0 is set to 1 to recover the clock from the LIU; 0 use internal clock

— All other bits are reserved and should be set to 0.

<code file>
The name of the codefile that gets downloaded to the board when it is reset. Codefiles for DSI SS7MD
Boards use the suffix .dc6.

<run_mode>
The protocols to be run. The following table shows the permitted values and their meanings.

7.1.2

LIU_CONFIG – Configure a T1/E1/J1 LIU

Synopsis

This command is used during initialization to configure the operating parameters for a T1/E1/J1 Line
Interface Unit (LIU).

Syntax

LIU_CONFIG <board_id> <liu_id> <liu_type> <line_code> <frame_format> <crc_mode> [<build_out>]

Example

LIU_CONFIG

0

0

5

1

1

1

0

Parameters

The LIU_CONFIG command includes the following parameters:

Feature

<run mode>

LSL

HSL

ATM

IMA

Low Speed Links

x

x

x

High Speed Links

x

x

x

ATM links

x

x

x

Multiple ATM links in IMA bundles

x

x

Advertising