7 Configuration Command Reference

Syntax

MTP HSL/LSL Links

MTP_LINK <link_id> <linkset_id> <link_ref> <slc> <board_id> <blink> <stream> <timeslot> <flags>
[<data_rate>]

Example

MTP_LINK 0 0 0 0 0 0 0 16 0x0006 TDM

ATM Links

MTP_LINK <link_id> <linkset_id> <link_ref> <slc> <board_id> <blink> <atm_stream> <vpi-vci> <flags> ATM

Example

MTP_LINK 0 0 0 0 3 0 0 8-100 0x0006 ATM

Common Parameters

The MTP_LINK command includes the following parameters:

<link_id>
The unique logical identity of the link. It must be in the range 0 to one less than the total number of
signaling links supported.

<linkset_id>
The logical identity of the linkset to which the link belongs. The linkset must already have been
configured using the

MTP_LINKSET

command.

<link_ref>
The logical identity within the linkset of the signaling link. It should be in the range 0 to one less than the
number of links in the linkset.

<slc>
The signaling link code for the signaling link. This must be unique within the linkset and is typically the
same as <link_ref>. The valid range is 0 to 15.

<flags>
A 32-bit value containing additional run-time options. The bit significance is as follows:

Note: If the <data_rate> is set to "ATM", only bits 0 to 2 are significant.

— Bit 0 is set to 1 to force the use of the emergency proving period during link alignment or 0 to use

the appropriate proving period according to the MTP3 recommendations.

— Bit 1 is set to 1 to cause a signaling link test (in accordance with ITU-T Q.707 / ANSI T1.111.7) to be

carried out before a link is put into service, or 0 if a test is not required.

— Bit 2 is set to 1 to cause a signaling link test (in accordance with ITU-T Q.707 / ANSI T1.111.7) to be

carried out every 30 seconds. This bit is ignored unless bit 1 is set to 1.

— Bit 8 is used to select the MTP2 error correction mode. It is set to 1 to select PCR (Preventive Cyclic

Retransmission) operation or 0 for the Basic Method of Error Correction.

— Bits 10 and 11 together select the appropriate operating bit rate for the link. The table below

specifies the appropriate values for 48, 56, or 64 kbits/s.

Bit 10

Bit 11

Data Rate

0

0

64 kbits/s

0

1

48 kbits/s

1

0

56 kbits/s

1

1

Reserved

Note: For framed HSL operation, these bits select the bit rate for
each slot of the HSL link.

Advertising