3 liu_msg_r_config, Liu_msg_r_config, Liu read configuration request – Dialogic DSI SS7MD User Manual

Page 63

Advertising
background image

63

Dialogic

®

DSI SS7MD Programmer’s Manual Issue 3

loop_mode
The diagnostic loopback mode. The following table shows the permitted values and their meanings.

prbs_gen
The Pseudo Random Bit Sequence (PRBS) generation mode. The following table shows the permitted
values and their meanings.

6.3.3

LIU_MSG_R_CONFIG – LIU Read Configuration Request

Synopsis

Message sent by the application to read back the current LIU configuration from the board.

Format

Description

This message is sent to the board to read back the current operating configuration of the Line Interface Unit
(LIU). The user should always request a confirmation message. The confirmation message indicates success
with a status value of 0 and contains the current configuration parameters in the parameter area of the
message.

Value

Description

0

Do not change diagnostic loopback mode

1

Disabled - remove any diagnostic loop

2

Payload loopback

3

Remote loopback

4

Local loopback

Value

Description

0

Do not change PRBS generation mode

1

Disabled - remove any PRBS generation

3

Generate PRBS pattern QRSS 20

MESSAGE HEADER

Field Name

Meaning

type

LIU_MSG_R_CONFIG (0x5e37)

id

liu_id (in the range 0 to one less than the number of LIUs)

src

Sending module ID

dst

MVD_module_ID

rsp_req

Used to request a confirmation.

hclass

0

status

0

err_info

0

len

40

PARAMETER AREA

Offset

Size

Name

0

40

Parameter area formatted in the same manner as the

LIU_MSG_CONFIG

message.

All fields should be set to 0.
The confirmation message contains the board configuration details.
The user should set the fields to 0 and the module writes the current
configuration parameters in the confirmation message.

Advertising