4-wire Direct Wire Connection

IMPORTANT:

A 4-wire connection is required for mobile homes

and where local codes do not permit 3-wire connections.

Direct wire cable must have 5 ft. (1.52 m) of extra length so

dryer may be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable, leaving

bare ground wire at 5" (127 mm). Cut 1

1

/

2

" (38 mm) from

remaining 3 wires. Strip insulation back 1" (25 mm). Shape

ends of wires into hooks.

1"

(25 mm)

3

1

2

"

(89 mm)

5"

(127 mm

)

3.

Prepare your 4-wire cable for

direct connection

To connect wires to terminal block, place hooked end of

wire under terminal block screw, facing to the right, squeeze

hooked end together and tighten screw.

4.

Connect wires to terminal block

5.

Prepare to connect neutral

ground wire and neutral wire

B

A

E

Remove center terminal block screw (B). Remove neutral

ground wire (E) from external ground conductor screw (A).

7.

Connect ground wire

F

E

A

Connect ground wire (green or bare) (F) of direct wire cable

to external ground conductor screw (A). Tighten screw.

B

E

C

6.

Connect neutral ground wire

and neutral wire

Connect neutral ground wire (E) and place hooked end (hook

facing right) of neutral wire (white or center wire) (C) of direct

wire cable under center screw of terminal block (B). Squeeze

hooked ends together and tighten screw.

Place hooked ends of remaining direct wire cable wires under

outer terminal block screws (hooks facing right). Squeeze

hooked ends together and tighten screws. Finally, reinsert

tab of terminal block cover into slot of dryer rear panel.

Secure cover with hold-down screw. Now, go to Venting

Requirements.