The Vent System charts provides venting requirements that

will help achieve best drying performance.

Special provisions for mobile home

installations:

The exhaust vent must be securely fastened to a noncombustible

portion of the mobile home structure and must not terminate

beneath the mobile home. Terminate the exhaust vent outside.

Determine vent path:

Select route that will provide straightest and most direct

path outdoors.

Plan installation to use fewest number of elbows and turns.

When using elbows or making turns, allow as much room

as possible.

Bend vent gradually to avoid kinking.

Use as few 90° turns as possible.

Determine vent length and elbows needed for

best drying performance:

Use following Vent System charts to determine type of vent

material and hood combinations acceptable to use.

NOTE: Do not use vent runs longer than those specified

in Vent system chart. Exhaust systems longer than those

specified will:

Shorten life of dryer.

Reduce performance, resulting in longer drying times

and increased energy usage.

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best

for your installation. Two close-clearance installations are shown.

Refer to the manufacturer’s instructions.

Over-The-Top installation (also available with one offset elbow)

Periscope installation

NOTE: The following kits for close clearance alternate

installations are available for purchase.

Venting Kits

For more information, call

1-800-901-2042, or visit us at

www.applianceaccessories.com. In Canada, call

1-800-807-6777 or visit us at www.whirlpoolparts.ca.

Part Number Descriptions
8171587RP

0–5" Metal vent periscope

4396037RP

0"-18" Metal vent periscope

4396011RP

18" - 29" Metal vent periscope

4396014

29" - 50" Metal vent periscope

4392892

In-Wall metal DuraVent™ Periscope

4396028

Sure Connect™ venting kit

(over-the-top installation)

4396009RP

5' Universal connect vent, flexible dryer venting

4396010RP

6' SecureConnect™ vent, flexible dryer venting

4396013RB

Dryer vent installer’s kit

4396033RP

5' flexible dryer venting with clamps

4396727RP

8' flexible dryer venting with clamps

4396004

Dryer offset elbow

4396005

Wall offset elbow

4396006RW

DuraSafe™ close elbow

4396007RW

Through-the-wall vent cap

4396008RP

4" steel dryer venting clamps - 2 pack

8212662

Flush mounting louvered vent hood 4"

Number of

90° turns

or elbows

Type

of vent

Box/louvered

hoods

Angled

hoods

0

Rigid metal

64 ft. (20 m)

58 ft. (17.7 m)

1

Rigid metal

54 ft. (16.5 m) 48 ft. (14.6 m)

2

Rigid metal

44 ft. (13.4 m) 38 ft. (11.6 m)

3

Rigid metal

35 ft. (10.7 m)

29 ft. (8.8 m)

4

Rigid metal

27 ft. (8.2 m)

21 ft. (6.4 m)

Vent System Chart