Arrangement of jumpers – Meinberg VP100 20NET User Manual
Page 25
Advertising
VP100/20NET
Page 25 of 25
7. ARRANGEMENT OF JUMPERS
JP7
JP16
JP8
JP14
JP9
JP15
JP18
JP11
JP17
JP10
U1
Function of jumpers:
JP14, JP15
RX_INFO input
– confirmation of the message's reception
(20 mA current loop): active / passive
JP16
selection of the RX_INFO input: RS232 / 20 mA current
loop
JP17, JP18
time-telegram output (20mA current loop): passive /
active
JP7, JP8, JP9, JP10, JP11
reserved (do not change)
The jumpers are shown in the following (default) positions:
JP14
active
JP15
active
JP16
RS232
JP17
passive
JP18
passive