Meinberg VP100 20NET User Manual
Page 7
Advertising
VP100/20NET
Page 7 of 25
JP7
JP16
JP19
VP100/20 NET
x
RS232
telegrams
VP100/20
RS232
x
telegrams
Fig. 3: The use of RS232 for the connection between the VP100/20 NET and the ordinary
VP100/20. The table shows the setting of jumpers in both displays.
JP7
JP8
JP9
JP10
JP11
JP14
JP15
JP16
JP17
JP18
JP19
VP100/20 NET x
x
x
x
x
passive passive 20 mA active active telegrams
VP100/20
20 mA passive passive active active x
x
x
x
x
telegrams
Fig. 4: The use of 20 mA current loop; here the outputs are active, and the inputs passive.
3
2
7
7
2
3
VP100/20 NET
Connector
OUT
VP100/20
Connector
IN
100
24
17
100
25
23
+V1
100
24
17
+V2
100
25
23
VP100/20 NET
Connector
OUT
VP100/20
Connector
IN