9

ENGLISH

Basic version

Advanced version

Information

Simple version

11

Use

ui

to select the item you want

to check, and then press

ENTER

.

Step4:Check

MultEQ

Please check the results

of the measured item.

Distance Check

Channel Level Check

Crossover Freq.Check

Speaker Config.Check

Next

[ENT]:Select

• Subwoofers may measure a greater reported

distance than the actual distance due to added
electrical delay common in subwoofers.

• If you want to check another item, press

RETURN

.

12

Use

ui

to select “Next” and then

press

ENTER

.

Set up speakers (Audyssey® Auto Setup)

Step 3

Calculating

Step 4

Check

13

Use

ui

to select “Store” and then

press

ENTER

.

Save the measurement results.

Step5:Store

MultEQ

Storing

Please wait...

[----------]

Step5:Store

MultEQ

Store

Cancel

[ENT]:Store

Please select “Store”

to store measurement

values.

• Saving the results requires about 10 seconds.
• If you do not want to save the measurement

results, use ui to select “Cancel”, then select
“Yes” using o p. All the measured Audyssey
Auto Setup data will be erased.

NOTE

During saving of measurement results, be sure
not to turn off the power.

14

Unplug the setup microphone from

the unit’s SETUP MIC jack.

15

Set Dynamic Volume®.

Finish

MultEQ

Storing complete.

Auto Setup is now

Turn on Dynamic Volume?

Yes :

No

finished.

[ ]:Select [ENT]:Exit

• For details of Dynamic Volume settings, see

page 47.

n

When turning Dynamic Volume on

• Use o to select “Yes”, and then press

ENTER

.

The unit automatically enters “Evening” mode.

n

When turning Dynamic Volume off

• Use p to select “No”, and then press

ENTER

.

Remote control operation

buttons

Move the cursor
(Up/Down/Left/Right)

Confirm the setting

Return to previous menu

NOTE

• If the result differs from the actual connection

status, or if “Caution!” is displayed, see “Error
messages” (vpage 10). Then carry out Audyssey
Auto Setup again.

• If the result still differs from the actual connection

status after remeasurement or the error message
still appears, it is possible that the speakers
are not connected properly. Turn this unit off,
check the speaker connections and repeat the
measurement process from the beginning.

• If you change speaker positions or orientation,

perform Audyssey Auto Setup again to find the
optimal equalizer settings.

Step 5

Store

10

On the

Step 2

screen, use

ui

to select “Calculate”, and then press

ENTER

.

Measuring results are analyzed, and the
frequency response of each speaker in the
listening room is determined.

Step3:Calculating

MultEQ

Calculating

[----------]

Please wait...

• Analysis takes several minutes to complete. The

time required for this analysis depends on the
number of speakers connected.
The more connected speakers there are, the
longer it takes to perform analysis.

Finish

NOTE

After performing Audyssey Auto Setup, do not
change the speaker connections or subwoofer
volume. In event of a change, perform Audyssey
Auto Setup again.

Advertising