Microsonic lcs-25/DDD/QP User Manual

Page 2

Advertising
background image

T1 + T2

T1



T2



T1 + T2



T1 + T2

T2

T1

Start here







T2



T1



T1 + T2



Ready



No function!

No function!

»F00«: no filter
»F01«: standard filter
»F02«: averaging filter
»F03«: foreground fil-
ter
»F04«: background
filter

Defines the strength
of the chosen filter.
»P00«: weak filter up
to
»P09«: strong filter

Minimum value: blind
zone
Maximum value: near-
window limit - 1

Low power mode

Hysteresis

switched output D1

Measurement filter

Filter strength

Foreground
suppression

Multiplex mode

device addressing

Multiplex highest

device address

Minimum value:
»001«
Maximum value: diffe-
rence between maxi-
mum range and de-
tect point - 1
During window mode
operation hysteresis
influences both detect
points.

No function!

Minimum value: sen-
sor-distant window
margin
Maximum value: 999
mm for mic+
25/...,mic+35/...,
999 cm for mic+
130/...,mic+340/...,
mic+600/...

Measurement range

Detection zone

sensitivity

Affects the size of the
detection zone.
»E01«: high
»E02«: standard
»E03«: slight

T1 + T2

T1

T2



T1 + T2

T2

T1











T1 + T2

T1

T2

T1 + T2

T2

T1













T1 + T2

T1

T2

T1 + T2

T2

T1













T1 + T2

T1

T2

T1 + T2

T2

T1













T1 + T2

T1

T2

T1 + T2

T2

T1













T1 + T2

T1

T2

T1 + T2

T2

T1













T1 + T2

T1

T2

T1 + T2

T2

T1













T1 + T2

T1

T2

T1 + T2

T2

T1













Delay in seconds bet-
ween the detection of
an object and the out-
put of the measured
distance in case of ob-
ject approach (beha-
ves as on-delay).
"00": 0 s (no delay)
up to
"20": 20 s response
time

Response time



Hysteresis

switched output D2

Minimum value:
»001«
Maximum value: diffe-
rence between maxi-
mum range and de-
tect point - 1
During window mode
operation hysteresis
influences both detect
points.

T1 + T2

T1

T2



T1 + T2

T2

T1











a Setting of additional functions in the LCA-2

Note
Changes in the Add-on
menu may impair the sensor
function.
A6, A7, A8 , A10 , A11, A12
have influence on the respon-
se time of the sensor.

Press on the LCA-2 simultaneously for about 13 s until «Add» is shown in the LED-display.

T1

T2

+

T1 + T2

T1

T2

T1 + T2

T2

T1













2



Press on the LCA-2 simultaneously for about 3 s until welcome message has passed

Start here

Optional setting of parameters using the LinkControl Adapter LCA-2 (Offline programming)

T1

T2

+

2





T2

T1



T2





T2

T1

T1 + T2

Set detect distance in
m or cm

For single detect
point press T2
until »- - -« is
displayed

Choose »

« for NCC or

»

« for NOC







For window mode
operation set far
detect point in
mm or cm







T2

T1











Set switched output D1

Ready

1

1

2

T1 + T2

T1

T1 + T2

T1 + T2







T2

T1



T2





T2

T1

T1 + T2

Set detect distance in
m or cm

For single detect
point press T2
until »- - -« is
displayed

Choose »

« for NCC or

»

« for NOC







For window mode
operation set far
detect point in
mm or cm







T2

T1





Set switched output D2

1

1

2

T1 + T2

T1

T1 + T2

T1 + T2







T2

T1



T2





T2

T1

T1 + T2

Set detect distance in
m or cm

For single detect
point press T2
until »- - -« is
displayed

Choose »

« for NCC or

»

« for NOC







For window mode
operation set far
detect point in
mm or cm







T2

T1





Set switched output D3

1

1

2

T1 + T2

T1

T1 + T2

T1 + T2



T2

T1

T1

T2

T1

T2

T1

T2

T1 + T2

Advertising