Technical data

Blind zone

Operating range
Maximum range

Angle of beam spread

0 to 30 mm
250 mm

0 to 65 mm
350 mm

350 mm
See detection zone

600 mm
See detection zone

Transducer frequency

Resolution, sampling rate

Reproducibility

Detection zones

for different objects:

The dark grey areas are determined

with a thin round bar (10 mm dia.)

and indicate the typical operating range

of a sensor. In order to obtain the light grey

areas, a plate (100 x 100 mm) is introduced

into the beam spread from the side.

In doing so, the optimum angle between

plate and sensor is always employed.

This therefore indicates the maximum

detection zone of the sensor.

It is not possible to evaluate ultrasonic

reflections outside this area.

320 kHz
0,18 mm

400 kHz
0,18 mm

± 0,15 %

± 0,15 %

Accuracy

Operating voltage U

B

Voltage ripple

Temperature drift internal compensated,

≤ 2%, may

be deactivated

1)

(0,17%/K without compensation

Temperature drift internal compensated,

≤ 2%, may

be deactivated

1)

(0,17%/K without compensation

9 V to 30 V DC, reverse polarity protection
±10 %

9 V to 30 V DC, reverse polarity protection
±10 %

No-load current consumption

Housing

< 70 mA
PBT

< 70 mA
PBT

ultrasonic transducer: polyurethane foam,
epoxy resin with glass content

ultrasonic transducer: polyurethane foam,
epoxy resin with glass content

Class of protection to EN 60 529

Norm conformity

Type of connection

Indicators

IP 65
EN 60947-5-2

IP 65
EN 60947-5-2

No
3 three-colour LEDs

No
3 three-colour LEDs

Programmable

Operating temperature

Storage temperature

Weight

Yes, with LCA-2 & LinkControl
-25°C to +70°C

Yes, with LCA-2 & LinkControl
-25°C to +70°C

-40°C to +85°C
120 g

-40°C to +85°C
120 g

Switching hysteresis

1)

Switching frequency

1)

Response time

1)

Time delay before availability

3 mm
11 Hz

5 mm
8 Hz

50 ms
< 300 ms

70 ms
< 300 ms

Order no.

Switched output

lcs-25/DDD/QP

lcs-35/DDD/QP

3 * pnp, U

B

-2 V, I

max

= 200 mA

switchable NOC/NCC, short-circuit-proof

3 * pnp, U

B

-2 V, I

max

= 200 mA

switchable NOC/NCC, short-circuit-proof

1) Can be programmed with LinkControl

0 to 200 mm
1.300 mm
2.000 mm
See detection zone
200 kHz
0,18 mm
± 0,15 %

Temperature drift internal compensated,

≤ 2%, may

be deactivated

1)

(0,17%/K without compensation

9 V to 30 V DC, reverse polarity protection
±10 %
< 70 mA
PBT
ultrasonic transducer: polyurethane foam,
epoxy resin with glass content
IP 65
EN 60947-5-2
No
3 three-colour LEDs
Yes, with LCA-2 & LinkControl
-25°C to +70°C
-40°C to +85°C
120 g
20 mm
6 Hz
110 ms
< 300 ms

lcs-130/DDD/QP
3 * pnp, U

B

-2 V, I

max

= 200 mA

switchable NOC/NCC, short-circuit-proof

3 pnp switched outputs

+U

B

-U

B

D1
D2
Com

1
2
4
5
3

U

lcs-25...

lcs-35...

0 cm

5 cm

10 cm

15 cm

20 cm

25 cm

30 cm

35 cm

ausgerichtete Platte

Rohr ø 10 mm

10 cm

5 cm

0 cm

5 cm

10 cm

0 cm

10 cm

20 cm

30 cm

40 cm

50 cm

60 cm

ausgerichtete Platte

Rohr ø 27 mm

20 cm

10 cm

0 cm

10 cm

20 cm

35 cm

lcs-130...

0 m

0,4 m

0,8 m

1,2 m

1,6 m

2 m

1,3 m

ausgerichtete Platte

Rohr ø 27 mm

0,8 m

0,4 m

0 m

0,4 m

0,8 m

microsonic GmbH • Hauert 16 • D-44227 Dortmund • Tel: +49 2 31 / 97 51 51-0 • Fax: +49 2 31 / 97 51 51-51 • E-Mail: [email protected] • www.microsonic.de The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features.

threaded bush

threaded bush

threaded bush

Plate

Round bar

Plate

Round bar

Round bar

Plate

Advertising