background image

2004/108/EC

Fig. 7:

Connecting dbk+4 to the LCA-2

The following settings can be
undertaken:
■ Teach-in of web or label material.
■ Spacing between transmitter and

receiver.

■ NOC/NCC

function

of

the

+U

B

-U

B

Colour
esp4

Colour
adapter cable

Brown

Blue

Brown

Blue

Pin

1
3

C3/Com

Grey

Grey

5

switched outputs.

■ Function of switched output D2.

Also available is a diagrammatic
representation of the readings.

Maintenance

No maintenance is need on the esp-
4. We would recommend cleaning
the sensor surfaces at the transmitter
and receiver should they become
very dirty. The best thing is to apply

some isopropanol onto a cotton
cloth and then wipe the surface
clean. Make sure that the reaction
time of the cleaner is kept down.
That means quickly wiping dry the
transducer surfaces.

Teach-in methods

Teach-in label dynamic

Place backing material with label between transmitter

and receiver.

Teach-in label static

a) Place only backing material between

transmitter and receiver.

Teach-in only for sheeting

(splice sensor)

Place web material between transmitter

and receiver.

Place control input C1 on logic 1 for 3 s until both LED

flash mutualy.

Pull backing material with labels among transmitter

and receiver with constant speed.

both LED flash green
simultaneously

Place control input C1 on logic 1 for 1 s.

one LED flashes green briefly,
one LED is static green

one LED is static green,
one LED flashes green

Place control input C1 on logic 1 for 6 s until

one LED turns off and one LED is on.

Pull only backing material among transmitter

and receiver.

one LED flashes green,
one LED is static green

Place control input C1 on logic 1 for 1 s.

b) Place backing material with label between

transmitter and receiver.

one LED flashes green briefly,
one LED is static green

one LED is static green,
one LED flashes green

Place control input C1 on logic 1 for 9 s until

both LEDs turn off.

Pull web material among transmitter

and receiver.

one LED flashes green briefly,
one LED is static green

Place control input C1 on logic 1 for 1 s.

one LED flashes green briefly,
one LED is static green

one LED is static green,
one LED flashes green

Normal operation

Place control input C1 on logic 1 for 1 s.

Move backing material with label between

transmitter and receiver.

one LED flashes green briefly,
one LED is static red

one LED flashes green,
one LED is static green

Place control input C1 on logic 1 for 1 s.

one LED flashes green briefly,
one LED is static green

one LED flashes green,
one LED is static green

=

>