Troubleshooting (cont.) – MovinCool CMW30 User Manual

Page 59

Advertising
background image

59

TROUBLESHOOTING (cont.)

If conditions persist after the above remedies have been performed, turn off the

unit, disconnect the power, and contact your MovinCool reseller or a qualified

technician.

Condition

Self-

Diagnostic

Codes

(Wall

mounted

controller)

Buzzer

Pattern

Possible

Cause

Remedy

Unit

does

not

operate.

LCD

displays

self-

diagnostic

codes.

E12

4

Compressor error

due to the following

conditions:

1. Unit is operating

outside the

operating condition

range.

2. Electromagnetic

noise interference

3. Compressor

locked up

Press RESET button

on the controller, and

turn off the circuit

breaker, then turn on

the circuit breaker.

Press ON/OFF

button on the

controller.

E13

4

Relay board error

due to the following

conditions:

1. Electromagnetic

noise interference

2. Electrostatic

discharge and

interruption

E23

4

Evaporator fan

motor over rotation

Check ducting of

intake and exhaust

air, and remove any

foreign object

preventing the air

flow.

Press RESET

button, then press

ON/OFF button.

Advertising