Continued

6. If the optional blower has been installed con-

nect blower to electrical source.

Option one:

Route blower electrical cord

through side or rear access door of fireplace.

Plug electrical cord into electrical outlet.

Option two:

Have a licensed electrician con-

nect blower to electrical source at junction box

inside fireplace.

7. Bend four nailing flanges on outer casing with

pliers (see Figure 7).

8. Attach fireplace to wall studs using nails

or wood screws through holes in nailing

flange.

9. Check all gas connections for leaks. See

Checking Gas Connections, page 17.

IMPORTANT:

When finishing your firebox,

combustible materials such as wall board, gyp-

sum board, sheet rock, drywall, plywood, etc.

may be butted up next to the sides and top of

the firebox. Combustible materials should never

overlap the firebox front facing. Firebox should

not be placed on top of carpet or other kinds of

fibrous material.

WARNING: Do not allow any

combustible materials to overlap

the firebox front facing.

IMPORTANT:

Noncombustible materials such as

brick, tile, etc. may overlap the front facing, but

should never cover any necessary openings like

louvered slots.

WARNING: Do not allow non-

combustible materials to cover

any necessary openings like

louvered slots.

WARNING: Never modify or

cover the louvered slots on the

front of the firebox.

WARNING: Use only non-

combustible mortar or adhe-

sives when overlapping the front

facing with noncombustible

facing material.

Figure 7 - Attaching Fireplace to Wall

Studs

Nails or
Wood
Screws

Nailing
Flanges

Mantel Clearances for Built-In Installation

NOTICE: Surface temperatures

of adjacent walls and mantels

become hot during operation.

Walls and mantels above the

firebox may become hot to

the touch. If installed properly,

these temperatures meet the

requirement of the national

product standard. Follow all

minimum clearances shown in

this manual.

If placing mantel above built-in fireplace, you must

meet minimum clearance between mantel shelf and

top of fireplace opening.

NOTICE: If your installation does

not meet the minimum clear-

ances shown, you must do one

of the following:

• raise the mantel to an accept-

able height

• remove the mantel

Advertising