Installation – Desa CF26PRA User Manual

Page 18

Advertising
background image

www.desatech.com

113897-01C

18

INSTALLATION

Continued

Figure 26 - Installing One-Piece Log Set

AUTO

OFF

ON

One Piece
Log Set

Burner

“U”-shaped
Cutout in
Chassis

Chassis

Figure 27 - Installing One-Piece Log set

(Top View)

One Piece Log Set

Burner
Ports

PRESSURE TESTING HEATER GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure 23,

page 17).

2. Open main gas valve located on or near gas

meter for natural gas or open propane/LP

supply tank valve.

3. Make sure control knob of heater is in the OFF

position.

4. Check all joints from equipment shutoff valve to

thermostat gas valve (see Figures 24 and 25, page

17). Apply noncorrosive leak detection fluid to all

joints. Bubbles forming show a leak.

5. Correct all leaks at once.
6. Light heater (see Operating Heater, page 20).

Check all other internal joints for leaks.

7. Turn off heater (see To Turn Off Gas to Appli-

ance

, page 21).

8. Replace front panel.

INSTALLING LOGS

WARNING: Failure to posi-

tion the parts in accordance

with these diagrams or failure

to use only parts specifically

approved with this heater may

result in property damage or

personal injury.

CAUTION: After installa-

tion and periodically thereafter,

check to ensure that no flame

comes in contact with any log.

With the heater set to HI, check

to see if flames contact any log. If

so, reposition logs according to

the log installation instructions

in this manual. Flames contact-

ing logs will create soot.

It is very important to install the logs exactly as

instructed. Do not modify logs. Only use logs

supplied with heater.
Place one-piece log set on grate to fit as illustrated

in Figure 26. Make sure back section of log set is

seated into “U”-shaped cutout in center of chassis

(see Figure 26). IMPORTANT: Make sure log does

not cover any burner ports (see Figure 27).

OPTIONAL WIRELESS HAND-HELD
REMOTE CONTROL ACCESSORIES

(CGHRCB & CGHRCTB Series)
Installing Receiver
1. Disconnect switch wires from the control

valve.

2. Remove screws and nuts.
3. Remove switch plate (see Figure 28). Discard

after removing.

Front

Back

Figure 28 - Switch Plate and Wiring

Harness (Switch Plate and Orientation

May Vary Depending On Model)

Wires

Nut

Nut

Screw

Front

Back

Advertising
This manual is related to the following products: