INSTALLATION

Continued

Installation must include an equipment shutoff

valve, union and plugged 1/8" NPT tap. Locate NPT

tap within reach for test gauge hook up. NPT tap

must be upstream from heater (see Figure 20).
IMPORTANT:

Install equipment shutoff valve

in an accessible location. The equipment shutoff

valve is for turning on or shutting off the gas to

the appliance.
Check your building codes for any special re-

quirements for locating equipment shutoff valve

to fireplaces.
Apply pipe joint sealant lightly to male NPT

threads. This will prevent excess sealant from

going into pipe. Excess sealant in pipe could result

in clogged heater valves.

WARNING: Use pipe joint

sealant that is resistant to liquid

petroleum (LP) gas.

We recommend that you install a sediment trap in

supply line as shown in Figure 20. Locate sediment

trap where it is within reach for cleaning. Install

in piping system between fuel supply and heater.

Locate sediment trap where trapped matter is not

likely to freeze. A sediment trap traps moisture and

contaminants. This keeps them from going into

heater controls. If sediment trap is not installed or

is installed wrong, heater may not run properly.

* Purchase the optional CSA design-certified

equipment shutoff valve from your dealer. See

Accessories, page 35.
** Minimum inlet pressure for purpose of input

adjustment.

3" Minimum

Gas
Control

Propane/LP
From External
Regulator
(11" W.C.** to
14" W.C.
Pressure)
Natural From
Gas Meter
(5" W.C.**
to 10.5" W.C.
Pressure)

CSA Design-Certified
Equipment Shutoff Valve
With 1/8" NPT Tap*

Approved Flexible
Gas Hose

Figure 20 - Gas Connection

Cap Pipe Tee

Nipple Joint

Sediment Trap

AUTO

OFF

ON

Figure 21 - Routing Flexible Gas Line

Equipment
Shut Off
Valve

Flexible Gas
Line from
Fireplace Gas
Valve Provided
with Fireplace

To Fireplace
Gas Valve

Figure 22 - Attaching Flexible Gas Lines

Together

Gas
Connector

Flexible Gas
Line from
Equipment
Shutoff Valve
Provided by
Installer

Equipment
Shutoff
Valve

To Gas
Supply

Outer
Casing

CONNECTING FIREPLACE TO GAS
SUPPLY

Installation Items Needed
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not provided)
1. Route flexible gas line (provided by installer)

from equipment shutoff valve into fireplace

through side or rear access holes in outer

casing (see Figure 21).

NOTICE: Most building codes

do not permit concealed gas

connections. A flexible gas line

is provided to allow accessibility

from the fireplace (see Figure 22).

The flexible gas supply line con-

nection to the equipment shutoff

valve should be accessible.

2. Apply pipe joint sealant lightly to male threads

of gas connector attached to flexible gas line

(see Figure 22). Connect flexible gas line

to flexible gas line attached to gas valve of

fireplace (see Figure 22).