Operation Section
26
ILL00889-00
MF1 
(Indoor
 Fan Motor)
Outdoor Heat
Exchanger
MF2
(Outdoor
 Fan Motor)
EXV (Electronic Expansion Valve)
Compressor
HPRS
(High Pressure Switch)
CTS1
(Indoor Pipe Thermistor)
ODS
(Outdoor Air Inlet Thermistor)
Indoor Heat 
Exchanger
Air In
Air In
EMV
Accumulator
OLC (Compressor Overload Relay)
CTS2 
(Compressor Pipe 
Thermistor)
4-Way Valve
RTS
(Indoor Air
 Inlet Thermistor)
CTS3 (Outdoor Pipe Thermistor)
Flow of Refrigerant: