Configuration and assembly

3.1 Connection to Multicon

Connection to Multicon may be performed in four different ways:

RS-422 cable (Ethernet cable) from an FR-2RU frame containing a Multicon

module

Multicon module mounted in the FlashCase-II unit

D-422-MG mounted in the FlashCase-II unit (requires two units, one in each end)

“In band management”. Please contact Nevion concerning this option.

3.2 Frame number selection in Multicon

Configure the desired frame (0 to 7) in Multicon by using the rotary switch at the internal
power board (Please see figure 3).

3.3 Module appearance in Multicon

The FlashCase-II unit (power board) will always appear as module number 6 of 10 in the
Multicon frame.

The mounted Flashlink modules will appear as numbers 1 to 5, with number 5 in the card
position furthest from the power board.

3.4 Internal power board, connections

The following connectors are in addition to the internal power connectors

One RJ-45 for RS-422 communication

One BNC for connection of a frame sync signal to the Flashlink modules

One 4pin header, GPI alarm output;

Pin1/pin2: Fan alarm

Relay output, shorted when in alarm status

Pin3/pin4: Voltage alarm

Relay output, shorted when in alarm status

Figure 2: Power board connections

BNC
(Sync)

RJ-45
(RS-422)

4pin
(GPI)

Rotary switch
(Frame number)