4 external power alarm, 5 power-up mode – Nevion SL-3GHD128128-RC User Manual

Page 14

Advertising
background image

SL-3GHD128128-RC

Rev. A


nevion.com | 14

3

87

3

87

42

126

42

126

In-/Outputs 127 and 128 are not in use in this router setup (3 layers).

4 layers:

Layer 1

Input

Layer 1

Output

1

1

1

1

2

2

2

2

32

32

32

32

Layer 2

Input

Layer 2

Output

1

33

1

33

2

34

2

34

32

64

32

64

Layer 3

Input

Layer 3

Output

1

65

1

65

2

66

2

66

32

96

32

96

Layer 4

Input

Layer 4

Output

1

97

1

97

2

98

2

98

32

128

32

128

3.4 External power alarm

The external power alarm can be switched according to the following pattern:

SW 7

Power alarm

OFF

Disables External Power Alarm

ON

Enables External Power Alarm

Default setting is External Power Alarm disabled.

3.5 Power-up mode

Switch 8 on the configuration switch defines the power up mode. The sublime router
provides two modes for powering up the system.

The power up options can be switched according to the following pattern:

SW 8

Power Up mode

OFF

Switches all outputs according to the buffered
information in the routers processor system.

ON

Switches all outputs to input 1.

Default setting switches all outputs according to the buffered information in the routers
processor system.