Connections

4.1 Router communication

You gain access to router for comm

unication purposes by connecting either the router’s

serial port to your computer and/or by using an Ethernet connection.

When multiple SL-D32P+ is connected together to make a bigger matrix, it is
not necessary to connect to more the one device at a time. The commands are
automatically distributed to all the devices.

4.1.1 Serial connection

Connection can be made through the serial port of the router; see also Chapters 2.4 and
2.5 for connection details.

The communication parameters are configurable. Please refer to the protocol
documentation of the appropriate communication/control protocol.

Example: The protocol parameters of the VikinX Compact routers are as follows:

Bit rate 19200 bit/s

Data bits 8 bits

Stop bits 1

Parity: No parity

For further details concerning this protocol, please refer to the following manual:

NCB Protocol.pdf

.

The DE9 female socket for the serial port of the router has the following pin-out:

Pin #

RS-232 mode

1

Not in use

2

Tx

3

Rx

4

Not in use

5

GND

6

GND

7

RTS

8

CTS

9

Do Not Connect!

Note that if the standard RS-232 cable specification (DCE) is followed:

A cable with Male+Male or Female+Female connectors at the cable ends is
used for Rx/Tx crossed connection, and

A cable with Male+Female connectors at the cable ends is used for a straight
through connection.

4.1.1.1 Maximum cable length (RS-232)
IEEE has specified the maximum cable length for an RS-232 connection to 15m. Longer
distances can be installed depending on the environmental conditions of the installation
site.

It is the responsibility of the installer / user to secure a proper installation of the
RS-232 connection.