53 | Troubleshooting

General Troubleshooting

Most operational malfunctions are not caused by faulty equipment but rather by improper
installation, or disregard for planning guidelines. Therefore, a complete fault diagnosis always
involves a thorough examination of the entire system. Often, the steam hose connection has not
been properly executed or the fault lies with the humidity control system. The following table
gives a list of possible malfunctions, the appropriate alarm or error message, details of their
cause, and notes on how to deal with each problem.

Table 15: Troubleshooting errors and warnings

Malfunction / Indication

Cause

Remedy

Min. Filling time too short

Error code: 1A/1B

Alarm1A

fillingtime

Error1B

Fillingtime

Steam cylinder heavily calcified.

Level in steam cylinder and level

in the float chamber do not match.

Carry out major servicing.

Level sensing unit faulty.

Test the level sensing unit is

operational by activating a drain

and noting if the LED sequence

changes, indicating a drain.

Internal safety chain

interrupted Error code: 2A/2B

Alarm2A

Safetychainint Error2

safetychainint

Connection to over-temperature

switch on steam cylinder is

broken or over-temperature

switch faulty.

Check connections or replace

over-temperature switch.

Steam cylinder overheating, over-

temperature switch has

responded.

Inspect steam cylinder, clean if

necessary. Replace over-

temperature switch.

Flat-band cable between control

and power board interrupted or

not connected.

Inspect connections, connect or

replace flat-band cable.

Door switch is disengaged.

Door switch safety connection is

closed by either pushing the

switch (such as when the door is

installed), or by pulling the switch.

Max. Filling time exceeded

(alarm message only) Error

code: 3A/3B

Alarm3A

Water supply

Water feed blocked (main water

tap closed, filter valve closed or

blocked). Water pressure too low.

Inlet valve does not open, filter

sieve in Inlet valve blocked or

inlet valve faulty. Feed hoses into

the steam humidifier not

connected or kinked. Level unit

not connected. Float in the level

unit sticking or level unit faulty.

Check water feed, open main

water tap, open or clean filter

valve. Raise water pressure

(range 1-10 bar). Inspect

electrical connections and fuse F2

on supply module. Clean filter

sieve or replace Inlet valve.

Inspect hoses into unit and

connect if necessary. Replace

faulty hoses. Connect level unit.

Clean or replace level unit.