Fuse Protection

The KAP-833 has a 10 Amp fuse mounted internally. This device wil1 shut off
power to the KAP-833 autopilot if a short-ciruit occurs inside the autopilot, or
between a power output and ground.

If this fuse blows repeatedly, recheck all your installation and wiring carefully. If
no error is found, consult your dealer or Technician.

KAP 833 Special Modes

To enter special modes enter number on keypad, press and hold GOTO then press
STANDBY.
To store the data press GOTO.
To exit special modes press MAIN
To use preset value press PRESET

Selection

901 Start compass calibration (CAL displayed)
902 Store compass calibration
903 Return to default compass calibration. (RES displayed)
904 Factory test for calibration.
905 Set limit switches(Analogue Volt Dis)
PORT ARROW (for port)/STBD ARROW (for Stbd)

908 Option remote:
r-1 Hand remote provision for 2
r-2 Active remote
r-3 Hand remote plus power steer on pin 3
r-4 Basic remote plus power steer on pin 3 in
standby mode.(Electric steering vessel)
r-5 When in power steer mode accept input from 3, Power steer mode from
other inputs pin 1 and 2 selected by 4 being pulled high for 1 and low for 2
to be active. Input 4 can be pulsed with a momentary push button to select
the mode.
r-6 When in standby the system goes to power steer mode accepting input
from 3, Power steer mode from other inputs pin 1 and 2 selected by 4 being
pulled high for 1 and low for 2 tp be active. Input 4 can pulsed with a
momentary push button to select the mode.

When setting limit switches in vessel with only power steer, Mode 908 allows
movement of the rudder using the encoder or port and starboard buttons .If remote
system is r-5 or r-6 select 908 mode prior to selecting 905 limit switch mode. Use
encoder to move rudder to desired position. Limits do not operate in this mode.