Thermal characteristics of common floor protection materials*

MATERIAL

CONDUCTIVITY (k)

PER INCH

RESISTANCE (R) PER INCH

THICKNESS

Micore

®

160

0.39

2.54

Micore

®

300

0.49

2.06

Durock

®

1.92

0.52

Hardibacker

®

1.95

0.51

Hardibacker

®

500

2.3

0.44

Wonderboard

®

3.23

0.31

Cement mortar

5.00

0.2

Common brick

5.00

0.2

Face brick

9.00

0.11

Marble

14.3 – 20.00

0.07 – 0.05

Ceramic tile

12.5

0.008

Concrete

1.050

0.950

Mineral wool insulation

0.320

3.120

Limestone

6.5

0.153

Ceramic board (Fibremax)

0.450

2.2

Horizontal still air** (1/8")

0.135

0,920**

* Information as reported by manufacturers and other resources
** For a 1/8" thickness. You cannot «stack» horizontal still air to accumulate R-values; you must separate each later of
horizontal still air with another noncombustible material.


2.7 Minimum masonry opening, clearances to combustibles, and floor protector