INSTALLATION INSTRUCTIONS

Exhaust Vent Pipe

Air Intake Pipe

0" min.

(0 mm)

0" min.

(0 mm)

0" min.

(0 mm)

12"

(300 mm)

Standards Compliance

This water heater must be installed in

accordance with these instructions, local

codes, and utility company requirements.
In the United States where local codes are not

available, use the latest edition of the American

National Standard/National Fuel Gas Code. A

copy of the Fuel Gas Code can be purchased

from either the American Gas Association, 400

North Capitol Street Northwest, Washington,

DC 20001, as ANSI standard Z223.1, or National

Fire Protection Association, 1 Batterymarch

Park, MA 02269 as NFPA 54.
In Canada, use the latest edition of the CSA

B149.1 Natural Gas and Propane Installation

Code and the Canadian Electrical Code,

CSA C22.1, Part 1.

Choosing a Location

WARNING:

Fire Hazard

Combustible construction refers to adjacent walls

and ceilings and should not be confused with

combustible or flammable products and materials.

Combustible materials, such as clothing, cleaning

materials, or flammable liquids, must not be

placed against or next to the water heater. Fire or

explosion could occur causing death, personal

injury, and/or product damage.

A gas-fired water heater should never be

installed in a space or room where liquids with

flammable vapors are used or stored. Such liquids

include gasoline, LP gas (butane or propane),

paint, adhesives and their thinners, solvents, or

removers. Flammable vapors carry long distances

from where they are used or stored. The open

flame of the water heater’s main burner can ignite

these vapors causing an explosion or fire.

NOTICE:

Elevating a gas-fired water

heater will reduce but NOT eliminate the possibility

of lighting the vapor of flammable liquids which

may be improperly stored or accidentally spilled.

NOTICE:

This water heater should not

be located in an area where leakage of the heat

exchanger or connections will result in damage

to the area adjacent to it or to lower floors of the

structures. When such areas cannot be avoided,

install a suitable catch pan with an adequate drain

under the water heater. This drain pan must not

restrict the combustion airflow.
The following requirements will ensure a safe

installation:
The water heater must be located in an area

where it won’t sustain damaged from moving

vehicles, flooding, etc. If the water heater is

installed in a garage, the direct ignition system

and main burner should be no less than 18 in.

(45 cm) above the garage floor.

The water heater should be installed as close as

possible to the vent exhaust and air intake. This

minimizes the vent length and the number of

elbows and joints required for venting.

The water heater should be installed with the

proper venting and exhaust materials.

General