3

IMPORTANT SAFETY INFORMATION

D A N G E R

FLAMMABLES

Flammable Vapors

Water heater has a main

burner flame.

The main burner flame:

1. which can come on

at any time and

2. will ignite flammable

vapors.

Vapors:

1. cannot be seen,

2. are heavier than air,

3. go a long way on the

floor and

4. can be carried from

other rooms to the

main burner flame by

air currents.

Vapors from flammable

liquids will explode and

catch fire causing death or

severe burns.

Do not use or store flammable

products such as gasoline,

solvents or adhesives in the

same room or area near the

water heater.
Keep flammable products:

1. far away from heater,

2. in approved containers,

3. tightly closed and

4. out of children's reach.

Installation:
Do not install water heater
where flammable products will
be stored or used unless the
main burner flame is at least

18" above the floor. This will
reduce, but not eliminate, the
risk of vapors being ignited
by the main burner flame.

Read and follow water heater warnings and instructions. If
owners manual is missing, contact the retailer or manufacturer.

Water Heater Venting Safety

3

DANGER:

Failure to install and properly

vent the water heater to the outdoors as outlined in

the “Venting” section of the Installation Instructions in

this manual will result in death from fire, explosion, or

asphyxiation from carbon monoxide. NEVER operate

this water heater unless it is properly vented and has

an adequate air supply for proper operation.
Be sure to inspect the vent terminal, the air intake,

and the vent system on the water heater for proper

installation at initial start-up and at least annually

thereafter. Refer to the “Care and Cleaning” section

of this manual for more information regarding vent

system inspection.

WARNINGS:

Gasoline and other flammable liquids, materials,

and vapors (including paint thinners, solvents,

and adhesives) are extremely dangerous. DO NOT

handle, use, or store gasoline or other flammable or

combustible materials anywhere in the vicinity of a

water heater or any other appliance. Be sure to read

and follow the labels on the water heater, as well

as the warnings printed in this manual. Failure to

do so can result in death, bodily injury, or property

damage.

Combustible construction refers to adjacent walls

and ceilings and should not be confused with

combustible or flammable products and materials.

Combustible materials, such as clothing, cleaning

materials, or flammable liquids, should never be

stored in the vicinity of this or any gas appliance.

Fire or explosion can occur causing death, personal

injury, and/or product damage. See page 29 for

clearances to combustible materials.

Follow vent manufacturer’s instructions for venting

installation, including additional clearances from

combustibles, to avoid conditions that can lead to

death, personal injury, and/or property damage.

Use tankless water heater manufacturer-approved

Schedule 40 PVC (foam core is not permitted at any

time), Schedule 80 PVC, CPVC, ABS, polypropylene,

or UL 1738-listed Category III Stainless Steel. No

other vent material is permitted.

Moisture in the flue gas will condense as it leaves

the vent terminal. In cold weather this condensate

can freeze on the exterior wall, under the eaves, and

on surrounding objects. Some discoloration to the

exterior of the building is to be expected. However,

improper location or installation can result in severe

damage to the structure or exterior finish of the

building.

For multiple-unit installation, a minimum distance

between vent terminations must be maintained to

prevent recirculation of vent gases. See page 39 for

information on venting and clearances to multiple

terminations.

CAUTIONS:

Ensure that the appliance vent is securely glued and

attached to the vent connection on the top of the

water heater. DO NOT USE SCREWS.

Do not operate without the condensate drain

connected and routed to the proper drain.