INSTALLATION INSTRUCTIONS

General

Every penetration of a floor or ceiling should be

sealed.

Failure to install and properly vent the water

heater to the outdoors as outlined on pages 33

through 46 can result in unsafe operation.

Long hot water lines should be insulated to

conserve water and energy.

The water heater and water lines should

be protected from exposure to freezing

temperatures.

Minimum water heater clearances from

combustible and noncombustible construction

are as follows:

– 1/2 in. (1.3 cm) for sides

– 0 in. (0 cm) for rear with support bracket(s)

– 12 in. (30 cm) from the bottom, top, and front

12" min.

(300 mm)

12" min.

(300 mm)

1/2" min.

(13 mm)

12" min.

(300 mm)

0"

(0 mm)

0" min.

(0 mm)

Sealed

• Do not install the water heater

outdoors or in bathrooms,

bedrooms, or any occupied rooms

normally kept closed.

• Do not install the water heater

where it is subject to vibrations.

• Do not install the water heater in a

recreational vehicle, mobile home,

boat, or other watercraft.

• Do not install the water heater

near vents for heating and cooling.

If necessary, maintain a minimum

clearance of 4 ft. (1.2 m).

Choosing a Location (cont.)