Installation instructions, Choosing a location (cont.), General – Paloma PHH-32 part 1 User Manual

Page 29

Advertising
background image

29

INSTALLATION INSTRUCTIONS

General

• Every penetration of a floor or ceiling should be

sealed.

• Failure to install and properly vent the water

heater to the outdoors as outlined on pages 33

through 46 can result in unsafe operation.

• Long hot water lines should be insulated to

conserve water and energy.

• The water heater and water lines should

be protected from exposure to freezing

temperatures.

• Minimum water heater clearances from

combustible and noncombustible construction

are as follows:

– 1/2 in. (1.3 cm) for sides

– 0 in. (0 cm) for rear with support bracket(s)

– 12 in. (30 cm) from the bottom, top, and front

12" min.

(300 mm)

12" min.

(300 mm)

1/2" min.

(13 mm)

12" min.

(300 mm)

0"

(0 mm)

0" min.

(0 mm)

Sealed

• Do not install the water heater

outdoors or in bathrooms,

bedrooms, or any occupied rooms

normally kept closed.

• Do not install the water heater

where it is subject to vibrations.

• Do not install the water heater in a

recreational vehicle, mobile home,

boat, or other watercraft.

• Do not install the water heater

near vents for heating and cooling.

If necessary, maintain a minimum

clearance of 4 ft. (1.2 m).