Upper Shell Removal

1. Remove screws along each

side of heater using 5/16"
nut-driver. These screws
attach upper and lower
shells together.

2. Lift upper shell off.
3. Remove fan guard.

125 SHELL REMOVAL

PFA/P 050

Upper
Shell

Fan Guard

Figure 6 - Upper Shell Removal

Never service heater while it is plugged in, operating, or
hot. Severe burns and electrical shock can occur.

Fan

IMPORTANT:

Remove fan

from motor shaft before
removing motor from heater.
The weight of the motor
resting on the fan could
damage the fan pitch.

1. Remove upper shell (see

above).

2. Use 1/8" Allen wrench to

loosen setscrew which
holds fan to motor shaft.

3. Slip fan off motor shaft.
4. Clean fan using a soft cloth

moistened with kerosene or
solvent.

5. Dry fan thoroughly.
6. Replace fan on motor

shaft. Place fan hub flush
with end of motor shaft
(see Figure 8).

7. Place setscrew on flat of

shaft. Tighten setscrew
firmly (40-50 inch-pounds/
4.5-5.6 n-m).

8. Replace fan guard and

upper shell.

Setscrew

Fan

Motor
Shaft

Figure 7 - Fan, Motor Shaft, and Setscrew Location

Setscrew

Motor
Shaft

Fan

Flush

Figure 8 - Fan Cross Section