125 AIR FILTER REMOVAL

PFA/P 046

Air Output, Air Intake,
and Lint Filters

1. Remove upper shell (see

page 10).

2. Remove filter end cover

screws using 5/16" nut-
driver.

3. Remove filter end cover.
4. Replace air output and lint

filters.

5. Wash or replace air intake

filter (see Preventative
Maintenance Schedule
,
page 8).

6. Replace filter end cover.
7. Replace fan guard and

upper shell.

IMPORTANT:

Do not oil

filters.

Figure 9 - Air Output, Air Intake, and Lint Filters

Air Intake Filter

Filter End
Cover

Air Output
Filter

Lint Filter

Fan Guard

Pump Pressure
Adjustment

1. Remove pressure gauge

plug from filter end cover.

2. Install accessory pressure

gauge (part number
HA1180).

3. Start heater (see Operation,

page 7). Allow motor to
reach full speed.

4. Adjust pressure. Turn relief

valve to right to increase
pressure. Turn relief valve
to left to decrease pressure.
Set pump pressure at 4 psi.

5. Remove pressure gauge.

Replace pressure gauge
plug in filter end cover.

Pressure
Gauge

Figure 11 - Adjusting Pump Pressure

Pressure
Gauge
Plug

Relief
Valve

Figure 10 - Pressure Gauge Plug Removal