WARNING

!

TROUBLE-

SHOOTING

OBSERVED FAULT

POSSIBLE CAUSE

REMEDY

Wrong pump pressure

Dirty air output, air intake
and lint filters

Dirty fuel filter

Dirt in nozzle

Dirty photocell lens

Bad flame-out control

See Pump Pressure

Adjustment, page 11.

See Air Output, Air Intake

and Lint Filters, page 11.

See Fuel Filter,

page 12.

See Nozzle, page 13.

Clean photocell lens.

Replace flame-out control.

Heater ignites, but
flame-out control
shuts off heater after
a short period of
time.

Never service heater while it is plugged in, operating, or
hot. Severe burns and electrical shock can occur.

Wrong pump pressure

Carbon deposits on spark
plug and/or improper
gap

Dirty fuel filter

Dirt in nozzle

Water in fuel tank

Electronic ignitor not
grounded

Bad electronic
ignitor

See Pump Pressure

Adjustment, page 11.

See Spark Plug, page 12.

See Fuel Filter,

page 12.

See Nozzle, page 13.

Drain and flush fuel

tank with clean
kerosene. See Storage,
page 8.

Make sure electronic ig-

nitor mounting is tight.

Replace electronic

ignitor.

Heater will not
ignite, but motor runs
for a short period of
time.

WARNING: High Voltage!

!

Motor does not start
when heater is
plugged in, fan turns
slowly or does not
turn.

Flame-out control not reset

Binding pump rotor

Reset flame-out control

button (see Figure 5,
page 7).

If fan is hard to

turn, see Pump Rotor,
page 14.