Theory of operation, Fuels, Warning – Desa BV125EDI User Manual

Page 6

Advertising
background image

6

THEORY CUTAWAY 125 EURO

THEORY OF

OPERATION

WARNING

!

FUELS

Use only kerosene or No. 1 fuel oil to avoid risk of fire or
explosion. Never use gasoline, naphtha, paint thinners,
alcohol, or other highly flammable fuels.

Clean
Heated
Air Out

Cool
Air
In

Output
Air
Filter

Figure 3 - Cross Section Operational View

Spark
Plug

Burner
Head

Fan

Motor

Air Pump

Intake
Air Filter

Nozzle

Heat Exchanger

Outer Shell

Exhaust Gases
Outlet

Exhaust gases cross over
from combustion chamber
to heat exchanger

Fuel
Tank

Air line
To Burner

Electronic
Ignitor

Exhaust
Gases

Air For Fuel
System

Air For Combustion
And Heating

Fuel

The Fuel System:

The air pump forces air through the air line. The air is then

pushed through the burner head nozzle. This air causes fuel to lift from the tank.
A fine mist of fuel is sprayed into the combustion chamber.

The Air System:

The motor turns the fan. The fan pushes air into and around

the combustion chamber. This air is heated and provides a stream of clean, hot air.
Exhaust gases are ducted out of the heater through a vent pipe. The user must
supply the vent pipe.

The Ignition System:

The electronic ignitor sends voltage to the spark plug.

The spark plug ignites the fuel and air mixture.

The Flame-Out Control System:

This system causes the heater to shut down

if the flame goes out.

Do not use heavy fuels such as No. 2 fuel oil or No. 2 Diesel. Using heavy fuels
will result in:

• clogged fuel filter and nozzle
• carbon build up on spark plug
• the need of non-toxic anti-icer in fuel during very cold weather

IMPORTANT:

Use a KEROSENE ONLY storage container. Be sure storage

container is clean. Foreign matter such as rust, dirt, or water will cause the flame-
out control to shut down heater. Foreign matter may also require you to clean fuel
system often.

Advertising