Jumper Settings for ELECTH-HPUMP and HE-HG

There are 6 jumpered pins on the thermostat circuit
board that identify whether your system is:
- Gas or electric heater
- Non-heat pump or heat pump system

You must ensure that these pins are set correctly for
your system. The pin location is shown in the following
diagram which is located at back side of ZTS-110.

Set to HG for Gas heat-fan controlled unit (

Default)

Fan will maintain off state.

Set to HE for Electrical heat-fan controlled unit
Fan will be turned on when there is heating output.

HG

HE

HG

HE

Note:
The HE and HG jumper controls the Fan when set to Auto in heating mode.
If user selects Fan ON at thermostat, the Fan will be turned on without considering the
HE-HG jumper selection.

Jumper Function Description

Set to ELECTH for non-heat pump system (

Default)

- When there is a heating request, thermostat will turn on W1
- When there is a cooling request, thermostat will turn on Y

Set to HPUMP for heat pump system
- When there is a heating request, thermostat will turn on Y and B
- When there is a cooling request, thermostat will turn on Y and O

ELECTH

HPUMP

ELECTH

HPUMP

Setup and Operations

Product Overview

Figure 8. ZTS-110

Description of Function Keys

Event mode

Day

Time

Program mode

Fan mode

Inclusion indication

Battery low indication

Mode

Current temperature

WAKE

AM

PROG ON

MO

HEAT

FAN ON

1

Key Description

Symbol

Increase value / Toggle selection

Decrease value / Toggle selection

Select fan mode; also the Backward function key in some menus

Change operation mode; also the Forward function key in some
menus

Select program mode:
PROG ON, OVERRIDE and PERMANENT OVERRIDE;
also the Confirm function key in some menus