CTS-M17 Installation, Operation and Maintenance Manual

B84450-001-000 RG

May 12, 2005

16

Options: 1200, 2400, 4800 or 9600 Baud.

14.

Password Selection

P

P

A

A

S

S

S

S

W

W

O

O

R

R

D

D

0

0

0

0

1

1

7

7

Factory default is 0017.

Press Enter and scroll up and down to choose a new password.

RECORD PASSWORD IN A SECURE PLACE.

Note: This item displays the current password, so it is important to

keep security in mind when passing this item in the presence of

bystanders.

If the password is lost, the unit must be returned to QEL to be reset.

15.

Exit Menu Tree

E

E

X

X

I

I

T

T

S

S

a

a

v

v

e

e

Press Enter, an * will appear beside Save. Press Up/Down to choose Save or

Abort. Press Enter/Accept to exit.

Note: Choosing Abort will discard all changes made since last

entering the menu system, including calibration values.

2.3 Hardware Configuration

2.3.1 Output Signals
Options are 4-20 mA or 2-10 V linear. Choose the option by moving the jumper on

JP1. On over-range concentrations the signal can exceed the range slightly.

Figure 3 - Output Signal Select Jumper (JP1)