Operating heater – Desa VSF30NT User Manual

Page 13

Advertising
background image

www.desatech.com

13

116307-01B

Note:

If pilot goes out, repeat steps 4 thru 7.

Thermostat models have a safety interlock

system. Wait one (1) minute before lighting

pilot again.

9. Turn control knob counterclockwise

to desired heating level. The main burner

should light.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

Figure 16 - Control Knob In The OFF

Position

OF

F

P

ILO

T

Control Knob

Ignitor Button
(Actual Ignitor may vary)

Figure 17 - Pilot

Ignitor
Electrode

Pilot
Burner

Thermocouple

D. Do not use this appliance if any part has

been under water. Immediately call a

qualified service technician to inspect the

appliance and to replace any part of the

control system and any gas control which

has been under water.

LIGHTING

INSTRUCTIONS

1. STOP! Read the safety information starting

on page 12.

2. Make sure equipment shutoff valve is

fully open.

3. Turn off any electric power to the appliance

if service is to be performed.

4. Turn control knob clockwise

to the

OFF position.

5. Wait five minutes to clear out any gas. Then

smell for gas, including near the floor. If you

smell gas, STOP! Follow “B” in the safety

information starting on page 12. If you donʼt

smell gas, go to the next step.

6. Turn control knob counterclockwise

to the PILOT position. Press in control knob

for five (5) seconds.

7. With control knob pressed in, push down

and release ignitor button. This will light

pilot. The pilot is attached to the front of

burner. Note: You may be running this

heater for the first time after hooking up to

gas supply. If so, you may need to press in

control knob for 30 seconds or more. This

will allow air to bleed from the gas system.

If needed, keep pressing ignitor button until

pilot lights. If ignitor does not light pilot,

refer to Troubleshooting, page 16 or contact

a qualified service person or gas supplier for

repairs. Until repairs are made, light pilot

with match. To light pilot with match, see

Manual Lighting Procedure

, page 14.

8. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob.

• If control knob does not pop up when

released, contact a qualified service person

or gas supplier for repairs.

OPERATING HEATER

Continued

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise

to the

OFF position.

2. Turn off all electric power to the appliance

if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise

to the

PILOT position.

Advertising