Installation – Desa VSF30NT User Manual

Page 9

Advertising
background image

www.desatech.com

9

116307-01B

INSTALLATION

Continued

Decide which method better suits your needs. Either

method will provide a secure hold for the heater.
Marking Screw Locations

WARNING: Maintain mini-

mum clearances shown in

Figure 4. If you can, provide

greater clearances from floor

and joining wall.

Mark three screw locations on wall as shown

in Figure 6).

Figure 6 - Wall Mounting Clearances

18

3

/

4

"

Min.

7"

Min.

9"

Min.

20,000 Btu Heaters

16

7

/

8

"

30,000 Btu Heaters

24

5

/

16

"

A

dj

oi

ni

ng

W

al

l

Insert

Mounting

Screws

Floor

Locate hardware packet behind left side door

of heater.
Attaching To Wall Stud Method
For attaching heater to wall studs
1. Drill holes at marked locations using 9/64"

drill bit. Holes must be level to prevent com-

plications with front panel.

2. Tighten screws until screw head is 1/8" away

from wall.

Attaching To Wall Anchor Method
For attaching heater to hollow walls (wall areas be-

tween studs) or solid walls (concrete or masonry).
1. Drill holes at marked locations using 5/16"

drill bit. Holes must be level to prevent com-

plications with front panel. For solid walls

(concrete or masonry), drill at least 1" deep.

2. Fold wall anchor as shown in Figure 7.
3. Insert wall anchor (wings first) into hole. Tap

anchor flush to wall.

4. For thin walls (1/2" or less), insert red key

into wall anchor. Push red key to “pop” open

anchor wings. IMPORTANT: Do not hammer

key! For thick walls (over 1/2" thick) or solid

walls, do not pop open wings.

Placing Heater On Mounting Screws
1. Locate two top vertical key slots on back end

panels of heater.

2. Place heater onto mounting screws.

Figure 7 - Folding

Anchor

Figure 8 - Popping

Open Anchor Wings

For Thin Walls

Figure 9 - Vertical Key Slots for Mounting

Heater to Wall

Vertical

Key Slots

5. Insert mounting screws into wall anchors.
6. Tighten screws until screw head is 1/8" away

from wall.

CONNECTING TO GAS SUPPLY

WARNING: This appliance

requires a 3/8" NPT (National

Pipe Thread) inlet connection to

the pressure regulator.

WARNING: A qualified service

person must connect heater to gas

supply. Follow all local codes.

WARNING: For natural

gas, never connect heater to

private (non-utility) gas wells.

This gas is commonly known

as wellhead gas.

IMPORTANT:

For natural gas, check gas line

pressure before connecting heater to gas line. Gas

line pressure must be no greater than 10.5" of wa-

ter. If gas line pressure is higher, heater regulator

damage could occur.