OPERATION: Refrigeration

Beginning at the compressor, the refrigerant is

compressed into a high temperature gas. The

discharge line directs this gas to the condenser. At

the condenser (air or water cooled) the gas is

cooled by either air or water and it then condenses

into a liquid. This high pressure liquid then goes

through the liquid line to the expansion valve.

The thermostatic expansion valve meters liquid

refrigerant into the evaporator, the volume of liquid

refrigerant depending upon the temperature of the

evaporator; warmer evaporators get more

refrigerant and colder evaporators get less.

At the evaporator, the refrigerant enters an area of

relatively low pressure, where it can easily “boil off”

or evaporate. As it evaporates, it absorbs heat

from the evaporator and whatever is in contact with

it (such as the water inside it). After the evaporator,

the refrigerant, now a low pressure vapor, goes

through the suction line back to compressor, where

the cycle is repeated.

MDT6N90

May 2001

Page 13

LIQUID LINE

SUCTION LINE

THERMOSTATIC

EXPANSION VALVE

EVAPORATOR

COMPRESSOR

FAN MOTOR

CONDENSER

REFRIGERATION SCHEMATIC

(AIR COOLED SHOWN)

DISCHARGE

LINE