Mdt6n90, Auger maintenance – Scotsman MDT6N90 User Manual

Page 19

Advertising
background image

AUGER MAINTENANCE

In some areas, the water supply to the ice maker

will contain a high concentration of minerals, and

that will result in an evaporator and auger

becoming coated with these minerals, requiring a

more frequent removal than twice per year. If in

doubt about the condition of the evaporator and

auger, the auger can be removed so the parts can

be inspected.

Note: Water filters can filter out suspended solids,

but not dissolved solids. “Soft” water may not be

the complete answer. Check with a water

treatment specialist regarding water treatment.

For more information on removal of these

parts, see REMOVAL AND REPLACEMENT.

Disconnect electrical power, and shut off the

water supply.

Use care when removing the auger, it has

sharp edges.

1. To remove the auger, remove the front and top

panels.

2. Drain evaporator using drain hose.

3. Remove bail clamp from over ice chute cover

and remove cover.

4. Unscrew and remove ice sweep.

5. Remove ice chute from evaporator.

6. Remove 4 allen screws holding breaker to

evaporator.

7. Pull up to remove auger.

After the auger has been removed, allow the auger

to dry: if the auger is not bright and shiny, it must

be cleaned.

Clean the auger and evaporator as required. DO

NOT HONE THE EVAPORATOR.

8. Replace the water seal.

9. Reverse to reassemble.

MDT6N90

May 2001

Page 19

BREAKER AND

AUGER ASSEMBLY

Moving Parts Hazard.

Disconnect electrical

power to the icemaker -

dispenser before

beginning.

Advertising