Operating appliance, Curing logs, Operating instructions for ga9050a – Desa LCF24 User Manual

Page 11: Continued

Advertising
background image

www.desatech.com

115043-01C

11

Shutting Off Appliance

Turn gas shutoff valve clockwise

to the

OFF position.

CURING

LOGS

During the 2-3 hour appliance break-in period,

you may detect an odor from the appliance

as the various paints and compounds used in

the manufacturing of this log set cure. This is

a normal and temporary situation that is not

cause for alarm. However, you may want to

provide extra ventilation to the room during

this time.

To ensure proper curing of the logs:

• Ignite a 2" flame and maintain it for 1

hour.

• Burn the logs in consecutive 1 hour periods

raising the flame an additional 2" to full

flame height for a total of three hours.

OPERATING

INSTRUCTIONS

FOR GA9050A

Note:

Operation instructions for GA9150A

Remote Ready Valve/Pilot Kit will be included

with the kit.

1. STOP! Read the safety information, page 10.

2. Make sure equipment shutoff valve is fully

open.

3. Press in and turn control knob clockwise

to the OFF position.

4. Wait five (5) minutes to clear out any gas.

Then smell for gas around log set and near

floor. If you smell gas, STOP! Refer to the

National Fuel Gas Codes, ANSI Z233.1/

NFPA 54, Section 5.3, Air for Combustion

and Ventilation. If you donʼt smell gas, go

to the next step.

5. Turn control knob counterclockwise

to the PILOT position and press in. Keep

control knob pressed in for five (5) seconds.

Note:

You may be running this log set for

the first time after hooking up to gas sup-

ply. If so, the control knob may need to be

pressed in for 30 seconds. This will allow

air to bleed from the gas system.

• If control knob does not pop up when

released, contact a qualified service person

or gas supplier for repairs.

OPERATING APPLIANCE

Continued

6. With control knob pressed in, push down

and release ignitor button. This will light

pilot. The pilot is attached to the rear of

the front burner. If needed, keep pressing

ignitor button until pilot lights.

Note:

If pilot does not stay lit, contact a

qualified service person or gas supplier for

repairs. Until repairs are made, light pilot

with match.

7. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob.

Note:

If pilot goes out, repeat steps 3

through 7.

8. Turn control knob counterclockwise

to the ON position. Burner should light. If

burner does not light, call a qualified service

person.

Ignitor

Control Knob

Pilot

FROM "PILOT" POSITION

SLIGHT PUSH TO

TURN OFF

PULL PUSH

TO LIGHT

ON

ON

FROM "PILOT" POSITION

SLIGHT

PUSH

T

O

TURN OFF

PULL

PUSH

T

O LIGHT

FROM "PILOT" POSITION

SLIGHT

PUSH

T

O

TURN OFF

PULL

PUSH

T

O LIGHT

ON

OFF

On

Off

OFF

OFF

Figure 12 - Ignitor and Control Knob

Figure 13 - Thermocouple and Pilot

Pilot
Burner

Thermocouple

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Appliance

1. Turn control knob clockwise

to the

PILOT position.

2. Press in and turn control clockwise

to the OFF position.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise

to the

PILOT position.

Advertising